- UC (Universal Battery Cycler)
- For simple battery test
Current ranges: 1~10A
Overview
Model. UC is available in sizes from 4 to 128 test Cells and are custom manufactured to meet specific customer's requirements. Model. UC can be provided by various types of jig for customers needs or battery types. As a rack mount type, It can be expanded up to 128 ch.
- For simpale battery test
- Control Mode : CC, CV, CP
- Current Ranges : 1~10A
- Interface : IEEE802.3(LAN)
- Voltage Measurement Accuracy : ±0.05% F.S
- Voltage Resolution : 16bits
- Current Measurement Accuracy : ±0.1%
- Current Resolution : 16bits
- Data Sampling Time : 100ms
- Cooling Method : Forced Air Cooling
- Current Rising Time : <10ms
- Up to 4 Current Ranges
- Input Power Supply : 1 Phase 220Vac 50/60Hz
Specification
It can be configured with a wide range of voltage, current ranges and fitted with optional hardware to provide a number of additional features and capabilities.
* The number of channels and modules that can be expanded depends on the size of the Cabinet (Small, Large).
Model Designation | Voltage | Current | Max. Number of Channels | Cabinet Size(W*D*H/mm) |
---|---|---|---|---|
UC 05-01 | 0~5V | 1 / 0.1 / 0.01 / 0.001A | 16 | 483*550*133 (Small) |
UC 05-06 | 0~5V | 6 / 0.6 / 0.06 / 0.006A | 8 | 483*550*133 (Small, Large) |
UC 05-10 | 0~5V | 10 / 1 / 0.1 / 0.01A | 4 | 483*550*133 (Small, Large) |
Application
Cylindrical type
Prismatic type
Pouch type